Thursday, 4 July 2019

Motor Efficiency Testing Labs In India

Motor Efficiency Testing Labs In India
Motor Efficiency Testing Labs In India


Are You Looking for Motor Efficiency Testing according to IEC 60034-2-1 / IS 15999 (Part 2/Sec 1)?

If you are looking for a Motor Efficiency Testing according to IEC 60034-2-1 Laboratory in India, ITC India Can Help You! ITC India one of the best Motor Efficiency Testing Service Provider in India. ITCIndia Can do Motor Efficiency Testing as per  IEC 60034-2-1 / IS 15999 (Part 2/Sec 1) Standard

Motor Efficiency Testing as per IEC 60034-2-1 / IS 15999 (Part 2/Sec 1) Standard

On this blog, I am not just going to pitch you to hire us for our Motor Efficiency Testing services but also going to provide a lot of valuable information on what, why and how we can do Motor Efficiency Testing as per IEC 60034-2-1 / IS 15999 (Part 2/Sec 1) Standard. Call on 0826440109108196980555 for Surge Testing laboratories.

Efficiency test method  IEC 60034-2-1 / IS 15999 (Part 2/Sec 1)

Applicable to:

Rotating Electric Machine: IEC 60034 is introducing to establish methods of determining efficiencies from tests and also to specify methods of obtaining specific losses.
  1. C.  Machine
  2. C. Synchronous
  3. Induction Machine (All Size in scope IEC 60034)
  4. Rotary Converters
  5. AC Commutator Motors
  6. Single Phase Induction Motor

Why high efficient Motors?

  • Save energy
  • Reduce operation cost
  • Reduce harmful greenhouse gases

Order of tests   IEC 60034-2-1

Step No. Description
1First stator winding resistance measurement at ambient temperature
2Remove accessible drive end sealing elements (without dismantling the motor)
3Clause 6.4.4.1  Rated load temperature test
4Second stator winding resistance measurement (immediately after 6.4.4.1)
5Clause 6.4.4.2 and 6.4.5.3  Load curve test with torque measurement (immediately after 6.4.4.1)
6Third stator winding resistance measurement (immediately after 6.4.4.2 and 6.4.5.3)
7Clause 6.4.2  No load test (immediately after third stator winding resistance measurement)
8Fourth stator winding resistance measurement (immediately after 6.4.2)


Determination of loss components must be performed in the following order

9Clause 8.2.2.3 Constant losses (8.2.2.3.1, 8.2.2.3.2 and 8.2.2.3.3)
Constant losses to Clause 8.2.2.3.1
(Friction and windage losses: 8.2.2.3.2)
(Iron losses: 8.2.2.3.3)
10Clause 8.2.2.4 Load losses (8.2.2.4.1.2 and 8.2.2.4.1.3)
Load losses to Clause 8.2.2.4.1:
(Stator and rotor winding losses
s, including temp. correction)
(8.2.2.4.1.2 and 8.2.2.4.1.3)
11Clause 8.2.2.5 Additional load losses (8.2.2.5.1 From a load test with torque measurement)
Additional load losses to Clause 8.2.2.5.1
(Residual losses)
12Clause 8.2.2.2  Calculate total losses
13Clause 8.2.2.1 Calculate the efficiency

Request for Motor Efficiency Testing Report as per IEC IEC 60034-2-1 / IS 15999 (Part 2/Sec 1) 

Why choose ITCIndia For Motor Efficiency Testing according to IEC 60601-1? 

ITCIndia is a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state of the art testing laboratories, assure a single source solution for meeting all applicable requirements, standards and voluntary schemes. And ITCIndia technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up to date knowledge of current and changing requirements.
Represented in over 5 locations in India, ITCIndia has an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The ITCIndia brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.
ITCIndia can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance

If Your Buyers Demanding for Motor Efficiency Testing – Contact Now!

Kindly send us the following Details, So that we can provide you with a quotation for the same:

  1. Product Name, Technical Specifications, and Brochure
  2. Product Images
  3. Total Number of Samples Required: 2

Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:


Wednesday, 19 June 2019

ISO 7175 Testing Labs | ISO 7175 Testing Laboratories

ISO 7175 Testing Labs | ISO 7175 Testing Laboratories
ISO 7175 Testing Labs | ISO 7175 Testing Laboratories


Are You Looking for ISO 7175 Testing?

If you are looking for an ISO 7175 Testing Laboratory in India, ITC India Can Help You! ITC India one of the best ISO 7175 Testing Service Provider in India. ITCIndia Can do ISO 7175 Testing
On this blog, I am not just going to pitch you to hire us for our ISO 7175 Testing services but also going to provide a lot of valuable information on what, why and how we can do ISO 7175 Testing. Call on 0826440109108196980555 for ISO 7175 Testing laboratories.

Request for Impact Testing Report as per ISO 7175

ISO 7175 Testing ISO 7175 Testing[/caption]
Part 1 - Safety requirements of Children Cots and folding cots for domestic use 
Part 2: Test Methods of Children Cots and Folding cots for Domestic Use 
Internal Length between 900mm to 1400 mm
This standard applies to cots that are Fully assembled and are ready to use. It is possible that additional requirements be applied for cots that can be converted into other items (e.g. changing units, playpens).
This standard does not apply to carry cots, cribs, cradles, rocking and swinging cots
Clause 4 of ISO 7175 part 1 specifies the SAFETY REQUIREMENT apply both before and after testing as per ISO 7175 part 2

Safety Requirement as per ISO 7175 -1

S.NClause Test Requirement
14.2.1Material and surfaceMust meet the requirement of ISO 8124-3
24.2.2Flammability of textile coated textile and plastic coverings  The maximum rate of flame shall be 30 m/s in accordance with ISO 8124-2
34.3Initial stabilityThe cot should not overturn in accordance with ISO 7175-2 (Cl 6.2 )
44.4.1.1Edges and protruding partsEdges shall be round and free of burrs and sharp edges
54.4.1.2Self-tapping screwThis screw shall not be used to fasten components when dismantling the cot for transportation.
64.4.1.3Labels and decalsShould not be used on the internal surface of cot sides and ends
74.4.1.4Small partsIn accordance with ISO 7175-2
84.4.1.5Castor and WheelsShould not be fitted exception are there
94.4.2.2Assembly holesNo accessible hole between 7 mm dia and 12 mm dia unless depth is less than 10mm.
104.4.2.3Distance between cot base and sides and end s25 mm cone shall not pass between cot base and sides and between cot base and ends.
114.4.2.4Opening in mesh sides and ends7mm cone shall not pass through the mesh openings.
124.4.2.5Distance between slats of cot base60 mm cone should not pass between two adjacent slats of the cot base.
134.4.2.6Opening in the mesh of cot base85 mm cone shall not pass through a cot base made of mesh.
144.4.3Head Entrapment on the exterior of the cotIn accordance with ISO 7175 - 2
154.4.4Shear and squeeze pointsIn accordance with ISO 7175 - 2
164.4.5Snag pointsIn accordance with ISO 7175 - 2
174.4.6Locking SystemAll cots should be equipped with at least two locking system
184.4.7Cot baseIn accordance with ISO 7175 - 2
194.4.8Sides and endsIn accordance with ISO 7175 - 2
204.4.9Cot rimNo filing shall be removed from cot rim when testing as per 7175-2, 6.6 bite test
214.5Final StabilityThe cot should not overturn as per cl 6.12 of ISO 7175-2
224.6Mattress size  The distance between mattress and sides shall be less than 30mm
235PackagingThe plasting covering should be tested as per ISO 8124-1
246Instruction for useRead carefully and alphabet size >5mm
Part 2 Test Method: Children’s cot and folding cots for domestic use
ISO 7175 Testing 2
This standard is designed to prevent the child from climbing out. Does not apply to swing and rocking chair.
Test equipment
Test forces must be applied with a suitable object like cones, cones of dia 7mm, 25mm, 45mm, 60mm, 65mm and 85mm made of plastic or other hard materials are required for applying force.
Measurements/ Testing
1 . Before testing, Assemble and inspect the cot visually. Tight all the fittings. Determine whether exposed edges, screws, bolts, zips and other fittings are rounded off and do not have sharp edges.
  1. Measure the height of sides, holes and distance between slats of cot base, mesh width, side slats, clearance between cot base and sides and ends.
  2. Impact testing
  3. Stability tests
  4. Locking and location device
  5. Bend testing
  6. Fatigue testing
  7. Endurance testing
  8. Static loading testing
  9. Inspection
  10. Mechanical testing
 For more information please visit www.itcindia.org or write info@itcindia.org 

Why choose ITCIndia For ISO 7175 Testing?

ITCIndia is a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state of the art testing laboratories, assure a single source solution for meeting all applicable requirements, standards and voluntary schemes. And ITCIndia technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up to date knowledge of current and changing requirements.
Represented in over 5 locations in India, ITCIndia has an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The ITCIndia brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.
ITCIndia can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance

If Your Buyers Demanding for ISO 7175  Testing – Contact Now!

Kindly send us the following Details, So that we can provide you with a quotation for the same:

  1. Product Name, Technical Specifications, and Brochure
  2. Product Images
  3. Total Number of Samples Required: 2

Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!

Mr Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:

Monday, 17 June 2019

EN/ IEC 62262 Impact Testing Labs | Impact IK Test Laboratories

Impact IK Testing Laboratories
EN/ IEC 62262 Impact Testing Labs | Impact IK Test Laboratories


Are You Looking for Impact Testing according to EN/IEC 62262?

If you are looking for an Impact Testing according to IEC 62262 Laboratory in India, ITC India Can Help You! ITC India one of the best Impact Testing Service Provider in India. ITCIndia Can do Impact Testing as per IEC 62262 Standard
On this blog, I am not just going to pitch you to hire us for our Impact Testing services but also going to provide a lot of valuable information on what, why and how we can do Impact Testing as per IEC 62262 Standard. Call on 0826440109108196980555 for Impact Testing laboratories.

EN/ IEC 62262 Impact Testing

Degrees of Protection Provided by Enclosures for Electrical Equipment Against External Mechanical Impacts (IK Code)
The IEC/EN 62262 standard defines an IK code which gives the equipment capacity to resist to mechanical impacts, on all the electrical enclosure surfaces.

Product on which IK is applicable :

  1. Electrical Enclosures
  2. Empty Enclosures
  3. CCTV Cameras
  4. LED street, Roadway and other lighting products
  5. Light Fixtures and many other products

Reference standards :

  1. IEC 60068-1
  2. 60068-2-75

Relevant product standards

We can execute impact testing describe above to any product standard. For Example:

  1. IEC/BS/EN 61429: Low voltage switch-gear and control assemblies
  2. IEC/BS/EN 62271: High Voltage switch-gear and control-gear.
  3. IEC/BS/EN 50130-5 Alarm System (Environment Test Method)
  4. IEC/ BS/EN  60598-1 Luminaries
  5. IEC 62696: Luminaries (Application of IK code as per  IEC/EN 62262)
  6. IEC /BS/ EN 62676-1-1 Video surveillance system for use in security applications.
  7. IEC /BS/EN 62208 Empty Enclosure for Low voltage switch-gear and control-gear assemblies.

Benefits of IK testing

It caters the evidence of the suitability of the enclosure for its intended environment.

  1. More durability
  2. High in demand
  3. Beneficial for the end user
IK CodeImpact Energy in joules Impact Testing
IK 010.14 J
IK 020.2 J
IK 030.35 J
IK 040.5 J
IK 050.7 J
IK 061 J
IK 072 J
IK 085 J
IK 0910 J
IK 1020 J
IK Code IK 00IK 01 to IK 05IK 06IK 07IK 08IK 09IK 10
Impact Energy-Less than 1 J1 J2 J5 J10 J20 J
R mm (Radius striking element)  -101025255050
Material-PolyamidePolyamideSteelSteelSteelSteel
Mass in Kgs -0.20.50.51.755
Pendulum Hammer-🗹🗹🗹🗹🗹🗹
Spring hammer-🗹🗹🗹🗷🗷🗷
Free Fall -🗷🗷🗹🗹🗹🗹
Spring Hammer Pendulum HammerFree Fall
Spring HammerPendulum HammerFree Fall

Request for Impact Testing Report as per EN/IEC 62262

Why choose ITCIndia For Impact Testing according to EN/IEC 62262?

ITCIndia is a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state of the art testing laboratories, assure a single source solution for meeting all applicable requirements, standards and voluntary schemes. And ITCIndia technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up to date knowledge of current and changing requirements.
Represented in over 5 locations in India, ITCIndia has an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The ITCIndia brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.
ITCIndia can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance

If Your Buyers Demanding for Impact IK Testing – Contact Now!

Kindly send us the following Details, So that we can provide you with a quotation for the same:

  1. Product Name, Technical Specifications, and Brochure
  2. Product Images
  3. Total Number of Samples Required: 2

Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:

Friday, 22 March 2019

Exit Sign Testing Labs In India

Exit Sign Testing Labs In India
Are You Looking for Exit Sign Testing Labs In India?

Are You Looking for Exit Sign Testing according to IEC 60598-1?

If you are looking for an Exit Sign Testing according to IEC 60598-1 Laboratory in India, ITC India Can Help You! ITC India one of the best Exit Sign Testing Service Provider in India. ITCIndia Can do Exit Sign Testing as per IEC 60598-1 Standard
On this blog, I am not just going to pitch you to hire us for our Exit Sign Testing services but also going to provide a lot of valuable information on what, why and how we can do Exit Sign Testing as per IEC 60598-1 Standard. Call on 08264401091/ 08196980555 for Exit Sign Testing laboratories.

Exit Sign Testing as per IEC 60598-1 Standard

S.NO.PRODUCTTesting as per standard
1.Exit SignTest as per IEC 60598-1:
Protection against electric shock
(Clause 8)
  Protection of the enclosure (Clause 9)
  Creepage distances and clearances
(Clause 11)
  Endurance test (Clause 12.3)
  The mechanical strength of screws and
nuts (Clause 14)

Request for Exit Sign Testing Report as per IEC 60598-1

Why choose ITCIndia For Exit Sign Testing according to IEC 60598-1?

ITCIndia is a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state of the art testing laboratories, assure a single source solution for meeting all applicable requirements, standards and voluntary schemes. And ITCIndia technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up to date knowledge of current and changing requirements.
Represented in over 5 locations in India, ITCIndia has an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The ITCIndia brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.
ITCIndia can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance

If Your Buyers Demanding for Exit Sign Testing – Contact Now!

Kindly send us the following Details, So that we can provide you with a quotation for the same:

  1. Product Name, Technical Specifications, and Brochure
  2. Product Images
  3. Total Number of Samples Required: 2

Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:


Wednesday, 6 March 2019

Surge Testing Labs In India

Are You Looking for Surge Testing Labs In India?
Are You Looking for Surge Testing Labs In India?

Are You Looking for Surge Testing according to IEC 61000-4-5?

If you are looking for a Surge Testing according to IEC 61000-4-5 Laboratory in India, ITC India Can Help You! ITC India one of the best Surge Testing Service Provider in India. ITCIndia Can do Surge Testing as per IEC 61000-4-5 Standard

Surge Testing as per IEC 61000-4-5 Standard

On this blog, I am not just going to pitch you to hire us for our Surge Testing services but also going to provide a lot of valuable information on what, why and how we can do Surge Testing as per IEC 61000-4-5 Standard. Call on 08264401091/ 08196980555 for Surge Testing laboratories.

Request for Surge Testing Report as per IEC 61000-4-5

Why choose ITCIndia For Surge  Testing according to IEC 60601-1?

ITCIndia is a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state of the art testing laboratories, assure a single source solution for meeting all applicable requirements, standards and voluntary schemes. And ITCIndia technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up to date knowledge of current and changing requirements.
Represented in over 5 locations in India, ITCIndia has an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The ITCIndia brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.
ITCIndia can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance

If Your Buyers Demanding for Surge Testing – Contact Now!

Kindly send us the following Details, So that we can provide you with a quotation for the same:

  1. Product Name, Technical Specifications, and Brochure
  2. Product Images
  3. Total Number of Samples Required: 2

Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!

Mr Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:



Tuesday, 1 January 2019

ISO 9847 Calibration of Field Pyranometers

ISO 9847 Calibration of Field Pyranometers
ISO 9847 Calibration of Field Pyranometers 

ISO 9847 Calibration of Field Pyranometers by Comparison to a Reference Pyranometer.

Are you looking for your pyranometer to be calibrated, ITC India Pvt Ltd has the facility to calibrate thermopile pyranometer at Lab and onsight. You are most welcome in ITC India Pvt Ltd for Pyranometer calibration. Either you can send the Pyranometer in the Lab or onsight calibration can be facilitated. Write to us at info@itcindia.org URL www.itcindi.org 
The calibration method is performed by our highly trained engineers and complies with type IIc Direct beam calibration of pyranometer as per international standard ISO 9847. 
Indoor calibration of field pyranometer is better as compared to outdoor in the following ways.
  • User control of test conditions
  • Results are independent of outdoor conditions
  • User convenience
The precision of the outdoor determination of the calibration factor of a field pyranometer is particularly dependent on sky conditions and solar elevation when performing measurements at low angles. Repeatability within any 21 points or more set of values of the same test scan performed at or near solar noon under stable irradiance conditions should be less than ± 0.5 % of the calibrated value of the instrument. If this requirement cannot be met, indoor calibration should be considered
To maintain performance, recalibration is usually recommended every two years, and a high-quality water-proof connector for the signal cable greatly simplifies the process.