Thursday 26 May 2016

LM-79 Testing for LED Flood lights, LM-79 Procedure, lm 79 Test Report

LM-79 Testing for LED Flood lights

LM-79 Testing for LED Flood lights

If you are looking for LM-79 Testing for LED Flood lights, ITC India NABL Accredited Electrical Safety Testing Laboratory provide LM-79 Testing for LED Flood Light includes accreditation for Solid State Lighting Luminaires, Total Flux Measurements (Luminous Efficacy) & Solid State Lighting Luminaires, Luminous Intensity Measurements.

The Testing to be conducted is as follows:-

LM-79 Testing on LED Flood lights Testing as per standard

Test to be conducted under LM 79 for LED Flood lights:

1. Measurement of Total Luminous Flux
& Luminous Efficacy
2. Color Characteristics (Chromaticity
Coordinates, Correlated Color
Temperature & Color Rendering Index) 
3. Light Intensity Distribution Test
IES LM-79-08 Testing Parameters for LED Flood lights
LM-79 Testing Approved Method: Electrical and photometric Measurements of Solid-state Lighting Product

LM-79 Test Photometric Results for LED Flood lights:

Colorimetric Parameters for LED Flood lights:

  • Chromaticity coordinates: (Chroma x / Chroma y / Chroma u(u’) / Chroma v / Chroma v’)
  • Correlated Color Temperature (CCT)
  • Duv Value
  • Color Ratio
  • Peak Wavelength (nm)
  • Half Bandwidth (nm)
  • Dominant Wavelength (nm)
  • Color Purity
  • Color Rendering Index (CRI – Ra)

Photometric Parameters for LED Flood lights:

  • Total Luminous Flux (Lumens)
  • Luminous Efficacy (Lumens/Watt)
  • Radiant Power (Watts)

Electrical Results for LED Flood lights:

  • Input Power (Watts)
  • Input Voltage (Volts )
  • Input Current (Amps)
  • Power Factor
  • Input Frequency (Hz)


Additional Parameters for LED Flood lights:

  • Stabilization Time (Light and Power) = 60 minutes
  • Test Geometry Configuration = 4π
  • Spectroradiometer = (Lisun LMS-9000A Plus)
  • Ambient Temperature = 25.0°C

Click Here to See Video How to Do LM-79 Testing ?


If you have any Query for LM-79 Testing on LED Flood lights

Contact Now!

Mr. Puneet Sharma M: 08196980555 E: ITCIndiaOne@Gmail.Com

If you are Interested You can Fill out the form below to receive a quote on the LM-79 Testing to get started:

Tuesday 24 May 2016

Cable gland Testing Laboratory, Cable Glands Test as per BS 6121, Cable gland Testing IEC- EN 62444- 2010

Tests on Cable Glands as per BS 6121 / IEC- EN 62444- 2010

Cable gland Testing Laboratory, Cable Glands Test as per BS 6121, Cable gland Testing IEC- EN 62444- 2010

Searches related to Cable gland Testing laboratory in india, Cable gland Testing Services, Cable gland Test lab, Cable Glands as per BS 6121 / IEC- EN 62444- 2010, Cable Glands Test as per BS 6121, Cable gland Testing bs en 50262, Cable gland Testing bs 6121 standard, en 50262 cable gland Testing, cable gland Testing iec 62444, cable gland Testing bs 6121, CABLE GLAND Testing STANDARDS
ITC India NABL Accredited Electrical Safety Testing Laboratory Service Provider of Cable Glands Testing as per BS 6121 / IEC- EN 62444- 2010, If you are looking for Cable Glands Testing Laboratory in Mumbai, Pune, Maharashtra, Ahmedabad, Gujarat, Bangalore, Karnataka, New Delhi, Baddi,Chennai, Tamil Nadu, Panchkula, Haryana, Ambala, Chandigarh, Ludhiana, Mohali, Punjab, kolkata west Bengal, India you can feel free to contact us.

Cable Gland Testing list Performed by ITCIndia:

  • Cable Retention Testing
  • Cable Anchorage Pull Testing
  • Cable Anchorage Twist Testing
  • Impact Testing
  • Torque Testing
  • Ingress Protection Testing
  • Electrical Continuity Testing
  • Insulation Resistance Testing
                                                                         

Cable Glands Testing Plan as per 62444

Sr.NoClauseTest Title
1.7.1Marking
2.8Construction
39Mechanical properties
4.9.2Cable Retention Test
59.3Cable anchorage Test for non-armorud Cable
69.4Cable anchorage Test for armorud Cable
79.5Resistance to Impact
810Electrical properties
910.2Ground Bond
1010.3.2Electrical current Test
1111Electromagnetic compatibility
121212 External influences (IP) codes
1312.2Resistance to corrosion
1413.Fire Hazard

If you are Interested Kindly Fill out the form below to receive a quote on the Cable Gland Testing to get started:

Contact Now! Puneet Sharma M: 08196980555 E: ITCIndiaOne@Gmail.Com

Monday 9 May 2016

LM 79 Testing for LED Street Light

LM 79 Test Laboratory for LED Street Light

 

LM 79 Test Laboratory for LED Street Light

ITC India NABL Accredited Electrical Safety Testing Laboratory provide LM-79 Testing for LED Street Light (45W & 60W) includes accreditation for Solid State Lighting Luminaires, Total Flux Measurements (Luminous Efficacy) & Solid State Lighting Luminaires, Luminous Intensity Measurements.

The Testing to be conducted is as follows(Testing as per standard):-

Test to be conducted under LM 79:

  1. Measurement of Total Luminous Flux & Luminous Efficacy
  2. Color Characteristics (Chromaticity  Coordinates, Correlated Color Temperature & Color Rendering Index)
  3. Light Intensity Distribution Test

IES LM-79-08 Testing Parameters,  LM-79 Testing Approved Method: Electrical and photometric Measurements of Solid-state Lighting Product

LM-79 Test Photometric Results:

Colorimetric Parameters:

  • Chromaticity coordinates: (Chroma x / Chroma y / Chroma u(u’) / Chroma v / Chroma v’)
  • Correlated Color Temperature (CCT)
  • Duv Value
  • Color Ratio
  • Peak Wavelength (nm)
  • Half Bandwidth (nm)
  • Dominant Wavelength (nm)
  • Color Purity
  • Color Rendering Index (CRI – Ra)

Photometric Parameters:

  • Total Luminous Flux (Lumens)
  • Luminous Efficacy (Lumens/Watt)
  • Radiant Power (Watts)

Electrical Results:

  • Input Power (Watts)
  • Input Voltage (Volts )
  • Input Current (Amps)
  • Power Factor
  • Input Frequency (Hz)

Additional Parameters:

  • Stabilization Time (Light and Power) = 60 minutes
  • Test Geometry Configuration = 4π
  • Spectroradiometer = (Lisun LMS-9000A Plus)
  • Ambient Temperature = 25.0°C

If you have any Query for LED Luminaires Testing, You can Feel free to Contact Us

If you are Interested You can Fill out the form below to receive a quote on the LM-79 Testing to get started:

Contact Now!

Puneet Sharma, M: 08196980555 E: ITCIndiaOne@Gmail.Com