Room Heater Testing



ITCIndia Can do Room Heater Testing as per IEC 60335-2-30, IS   302-2-30, ASTM E1509 Standards

If you are looking for Room Heater testing Laboratory for Room Heater In India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam and other city, ITCINDIA NABL Approved Electrical Safety testing Lab Can Help You! ITC India one of the best Room Heater testing Laboratory in India.
We, “Institute of Testing and Certification India Pvt. Ltd” are a leading testing company/laboratory having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811.  The Laboratory is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.

Applicable Standards:

  1. IEC 60335-2-30
  2. IS 302-2-30
  3. ASTM E1509            

Essential Tests:

  1. Protection against access to live parts
  2. Power input and output at operating temperature
  3. Heating
  4. Temperature rise
  5. Leakage current and electric strength
  6. Transient overvoltage
  7. Moisture resistance
  8. Overload protection
  9. Stability and mechanical hazards
  10. Mechanical strength
  11. Provision for earthing
  12. Insulation resistance
  13. Creepage and air clearance

Some important test Results are shown in tabular form

Table A:


Cl. 10.1TABLE: Power input deviation
P
Input deviation of/at:P rated (W)P measured (W)Allowed DeviationRemark
230V, 50Hz2000W1930W+5% & -10%Within limit

Table B:

Cl. 11.8TABLE: HeatingP

Test voltages (V)              :At 1.15 * 2000W = 2300 W-

Ambient (°C)      :25°C-
Thermocouple  locationsTemp. Measured (oC)Max. Rise Temp. (oC)Max Limit (oC)
a) Internal Wiring724750
b) External Wiring64.139.150
c) Handle54.529.560
d) Switch492430

Table C:


Clause. No.Test ConductedTest ConditionsTest  requirementResults


Cl. 13.2

Leakage Current Test
Motor operated appliance: 1.06 times of rated voltage: Between : Each pole of the supply source and the accessible metal partShall not exceed 0.75mAPass Imea:24µA

Cl. 13.3
High Voltage TestTest voltage: : 1000 V Test Duration: 1 min.
Test Part: Between live part and screw on the body.
Shall withstand without  breakdownPass
No flashover or break down occur
Cl. 14
Impulse Test (Transient over voltages)
Transient Overvoltage: 2920V The impulse test voltage is applied three times for each polarity with intervals of at least 1s.There shall be no flashover.Pass, No flash over occur.


Cl. 27.5

Earth Contact Resistance Test
Test Current: 25A
Test Part: Between protective earth terminals and accessible metal Part
Calculated Earth Contact Resistance from current & drop in voltage shall not exceed 0.1 Ω)Pass
Rmea:-22.6mΩ

Table D:

Cl. 29:  Clearances, creepage distances and solid insulation

Minimum distance (mm)Measured distance (mm)Verdict
Clearances
- Basic insulation (at Rated Impulse Voltage 2500)1.5mm>1.5mmP
Creepage  distances
- Basic Insulation (at Working voltage 250V for pollution Degree 3, Material Group IIIa/IIIb)
4mm

>4mm

P

For your better understanding, we are going to show you the Room Heater Test report of latest LED in the following:

Learn more about this Room Heater test >

If you’re Buyers Demanding for Room Heater Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:

Submit your requirement for Testing:-

Full Name


E-mail:


Describe Your Requirements with Technical Details: