Thermal Testing for LED Lights, Thermal Testing of LEDs, Thermal testing of road luminaires
If you are looking for Thermal Testing Laboratory for LED Lighting In your Area, ITCIndia NABL Approved Electrical Safety testing Laboratory In India. ITC India one of the best Thermal Testing Laboratory in India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam.
ITCIndia “Institute of Testing and Certification India Pvt. Ltd” are a leading testing lab having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811. ITCIndia Lab is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.
Thermal test is one of the important tests while testing LED luminaries, so we would like to have its basic knowledge.
Thermal test is performed for normal and abnormal conditions. We will peep inside both the conditions respectively.
The motive of thermal test is that the Lamp, part of the luminary, supply wiring, mounting surface should not attain the temperature which can cause injury. The parts like handles should not be too hot to be touched. Same scenario is for the track mounted luminaries are there. Track mounted Luminaries are tested as per clause 12.4.1. Draught proof chamber is specially designed for this particular test. While performing the test, the through wiring and the looping in wiring shall be loaded to the maximum value allowed by the size of the wire, or at a value prescribed by the manufacturer in the installation instructions.
After the test, none of the temperature shall exceed the values given in table 12.1 & 12.2 of IEC 60598-1.
While performing the thermal test in abnormal condition, luminaries are tested in abnormal conditions. The temperature shall not exceed as mentioned in table 12.3, 12.4, and 12.5. If the luminary possesses motor, the test is performed in most critical condition.
Clause 12.6 is applied to the luminary classified for mounting on normally flammable surfaces with a control gear. Clause 12.7 is thermal test in regard to fault conditions in lamp control gear or electronics devices incorporated in thermoplastics luminaries.
Temperature Measurement Data as per client specification
The sample was operated until constant temperatures were obtained. A temperature was considered
constant if the sample was operating for at least three hours and upon three successive readings - taken at
15 minute intervals - were within one degree and were not rising.
Thermocouples were attached at locations described in the results by means of cement made of water
constant if the sample was operating for at least three hours and upon three successive readings - taken at
15 minute intervals - were within one degree and were not rising.
Thermocouples were attached at locations described in the results by means of cement made of water
Table-1
No. of LED’s: | 48 | Ambient Temperature: | 25°C ± 1°C | ||
Total no. of test points: | 55 | No. of Rows | 4 | ||
Sr. no. | Measured Temperature at Pt. | Measured Temperature | |||
Row-1 | |||||
1 | LED 1 (Ts) | 56.3 | |||
2 | LED 2 (Ts) | 56.7 | |||
3 | LED 3 (Ts) | 55.8 | |||
4 | LED 4 (Ts) | 55.1 | |||
5 | LED 5 (Ts) | 56.4 | |||
6 | LED 6 (Ts) | 55.9 | |||
7 | LED 7 (Ts) | 55.2 | |||
8 | LED 8 (Ts) | 57.1 | |||
9 | LED 9 (Ts) | 57.4 | |||
10 | LED 10 (Ts) | 56.6 | |||
11 | LED 11 (Ts) | 56.9 | |||
12 | LED 12 (Ts) | 57.2 | |||
Row- 2 | |||||
13 | LED 13 (Ts) | 54.6 | |||
14 | LED 14 (Ts) | 55.8 | |||
15 | LED 15 (Ts) | 57.6 | |||
16 | LED 16 (Ts) | 57.9 | |||
17 | LED 17 (Ts) | 55.5 | |||
18 | LED 18 (Ts) | 57.4 | |||
19 | LED 19 (Ts) | 56.9 | |||
20 | LED 20 (Ts) | 57.6 | |||
21 | LED 21 (Ts) | 56.5 | |||
22 | LED 22 (Ts) | 57.5 | |||
23 | LED 23 (Ts) | 56.3 | |||
24 | LED 24 (Ts) | 56.9 | |||
Row -3 | |||||
25 | LED 25 (Ts) | 55.5 | |||
26 | LED 26 (Ts) | 54.9 | |||
27 | LED 27 (Ts) | 55.9 | |||
28 | LED 28 (Ts) | 56.0 | |||
29 | LED 29 (Ts) | 56.3 | |||
30 | LED 30 (Ts) | 55.9 | |||
31 | LED 31 (Ts) | 56.2 | |||
32 | LED 32 (Ts) | 54.3 | |||
33 | LED 33 (Ts) | 55.2 | |||
34 | LED 34 (Ts) | 55.9 | |||
35 | LED 35 (Ts) | 56.3 | |||
36 | LED 36 (Ts) | 56.8 | |||
Row- 4 | |||||
37 | LED 37 (Ts) | 55.5 | |||
38 | LED 38 (Ts) | 55.9 | |||
39 | LED 39 (Ts) | 56.1 | |||
40 | LED 40 (Ts) | 57.5 | |||
41 | LED 41 (Ts) | 56.2 | |||
42 | LED 42 (Ts) | 55.9 | |||
43 | LED 43 (Ts) | 57.2 | |||
44 | LED 44 (Ts) | 57.7 | |||
45 | LED 45 (Ts) | 57.3 | |||
46 | LED 46 (Ts) | 56.9 | |||
47 | LED 47 (Ts) | 57.5 | |||
48 | LED 48 (Ts) | 57.8 | |||
TP Point Pcb -1 | |||||
1. | TP | 56.5 | |||
TP Point Pcb -2 | |||||
1. | TP | 55.6 | |||
TP Point Pcb -3 | |||||
1. | TP | 55.9 | |||
TP Point Pcb -4 | |||||
1. | TP | 56.1 | |||
TP Point Pcb -5 | |||||
1. | TP | 56.2 | |||
TP Point Pcb -6 | |||||
1. | TP | 56.9 | |||
Ballast Tc Test point | |||||
1. | Tc | 53.4 | |||
ITC India Pvt. Ltd. is accompanying which possesses the full scope of IEC 60598-1. For any query please write us at …..