Thursday 23 April 2015

IP X4 Testing


 

ITC INDIA NABL Accredited Electrical Safety Testing laboratory  Can do Ingress protection against IPX4 according to IEC/EN:60529.

IPX4:

Water splashing against the enclosure from any direction shall have no harmful effect.

Specification :

  Oscillating tube with as numeral 3  Spray ± 180° from vertical, distance max. 200 mm.
Rate of Flow:

                    a)      0,07 l/min ± 5 % per hole, multiplied by number of holes.
                    b)      10 l/min ± 5 %.

Duration of the Test :

 10 min , 1 min/m² at least 5 min

If you have any query regarding testing and Certification. Kindly send us your testing requirements with the product technical details to submit you our testing charges.

We are waiting for your earliest reply.

You can call or write us for any clarification.

Thanks & Regards,
Puneet Sharma
M: +91.8196980555
E-mail:-(itcindiaone@gmail.com)
ITC India Pvt. Ltd

No comments:

Post a Comment