Wednesday, 31 January 2018

Stationary Lead Acid Battery Testing Laboratory

Stationary Lead Acid Battery Testing Laboratory
Stationary Lead Acid Battery Testing Laboratory

Stationary Lead Acid Battery

IEC 60896-22 is applicable to  :-

  1. All stationary Lead-acid cells
  2. Monobloc batteries of the valve regulated type
  • For Float charge application: They can be permanently connected to a load and d.c. power supply.
  • In a static location: not generally moved from place to place.
They are incorporated into stationary equipment or installed in battery room.

These kinds of batteries can be used in

  • Telecom
  • UPS
  • Utility switch
  • Emergency power or similar applications
Objective of IEC 60896-22 :- It specify the methods of tests for all types and construction of valve regulated stationary Lead acid batteries and monobloc batteries.

Does not applicable :

  • lead-acid cells and monobloc batteries used for vehicle engine starting applications
  • solar photovoltaic energy systems
  • general purpose applications
There is a list of tests performed on the batteries for safe operation characteristics, durability Characterstics & performance Characteristics.

Safe operation characteristics

Test ClauseMeasurePurpose
6.1Gas emissionTo determine the emitted gas volume
6.2High Current ToleranceTo verify the adequacy of current conduction
cross- sections
6.3Short circuit current & d.c internal resistanceTo provide data for the sizing of fuses in the
exterior circuit
6.4Protection against internal ignition from external spark sourcesTo evaluate the adequacy of protective features
6.5Protection against ground short propensityTo evaluate the adequacy of design features
6.6Content and durability of required markingsTo evaluate the quality of the markings and the
content of the information
6.7Material identificationTo ensure the presence of material identification
markings
6.8Valve operationTo ensure the correct opening of safety valves
6.9Flammability rating of materialsTo verify the fire hazard class of battery materials
6.10Intercell connector performanceTo verify the maximum surface temperatures of
the connectors during high rate discharges

Performance characteristics

Test Clause Measurepurpose
6.11Discharge capacityTo verify the available capacities at selected
discharge rates or discharge durations.
6.12Charge retention during storageTo provide storage duration data
6.13Float service with daily dischargesTo determine cyclic performance under float charge conditions
6.14Recharge behaviorTo determine the recovery of capacity or
autonomy time after a power outage

Durability Characteristics

Test Clause Measurepurpose
6.15Service life at an operating temperature of
40 °C
To determine the operational life at elevated temperatures
6.16Impact of a stress temperature of 55 °C or
60 °C
To determine the influence of high stress
temperatures on cell or monobloc battery life
6.17Abusive over-dischargeTo determine the expected behaviour when excessive capacity is discharged
6.18Thermal runaway sensitivityTo determine the expected times to establish a condition of escalating current and temperature
6.19Low temperature sensitivityTo determine the sensitivity toward damage induced by electrolyte freezing
6.20Dimensional stability at elevated internal
pressure and temperature
To determine the propensity of the cell or
monobloc battery to be deformed by internal
pressure and at elevated temperature
6.21Stability against mechanical abuse of units
during installation
To determine the propensity of the cell or
monobloc battery to fracture or leak when
dropped.

If Your Buyers Demanding for Stationary Lead Acid Battery  Testing – Contact Now!

Kindly send us the following Details, So that we can provide you quotation for the same:

  1. Product Name, Technical Specifications and Brochure
  2. Product Images
  3. Total Number of samples Required: 2

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:


Friday, 19 May 2017

Testing For Electric Fence Energizer

 
Electric Fence Energizer Testing

Are you looking for Fence Energizer Testing Laboratory?

If you are looking for Solar Fence Energizer Testing laboratory, then you are at the right place. (ITC India Pvt Ltd).  ITC India one of the best Solar Fence Energizer Testing Laboratory in India. ITCIndia NABL Approved  in electrical ,electronics, and Photometric Division.  If you are Interested for Energizer Testing, then ITC India Can Help You!
For More Information You Can Check our certificate no. T-3509T-3570 and T-1811.

Fence Energizer Testing Standards:

  • IEC 60335-2-76
  • IS 302-2-76

Energizer Testing Test as per IS 302-2-76, IEC 60335-2-76

  1. Protection against Electric Shock,
  2. Electrical Insulation at operating

    Temperature

    3. Moisture Resistance
    4. Insulation resistance
    5. Stability and mechanical hazards
    6. Mechanical strength
    7. Constructions Internal Wiring,
    8. Components,
    9. Cord grip and cord guard,
    10. Terminals for external conductors,
    11. Provision for earthing,
    12. Screws and connections,
    13. Creepage distances and clearances,
    14. Resistance to heat fire and tracking

People Searches related to Fence Energizer Testing:

Solar Zatka Machine Testing, Testing For Solar Fence Guard, Solar Fence Guard Testing , Security Energizers Testing , Security electric fencing Testing , Electric Fence Energizer SMS Controller Testing, Searches related to Security Energizers Testing , electric fence energizer Testing price in India, solar fencing energizer Testing price, solar fencing Testing cost, electric fence energizer Testing India, electric fencing Testing India, electric fence Testing India price, Testing For Solar Fence Guard, Electric Fence Energizer Testing Laboratory, Contact us for Electric Fence Energizer Testing, Get FREE Quote For Fence Energizer Testing, Solar Electric Fence Energizer Testing Delhi, Mumbai, Gurgaon, Noida, Chennai, Hyderabad, Bengaluru, Kolkata, Pune, Ahmedabad, Greater Noida, Uttar Pradesh, Lucknow, Manesar, Haryana, Chandigarh, Kandla, Pune, Maharashtra, Chikkalthana, Nashik, Hospet, Karnataka, Sriperumbudur, Tamil Nadu, Meenambakkam, Tirupur, Coimbatore, Tuticorin, Korba, Raipur, Bhilai Steel Plant, Bhiwandi, Vijayawada, Firozabad, Panna, Panipat, Channapatna, Varanasi, Moradabad, Bareilly, Jamshedpur, Bhagalpur, Tiruppur, Rajahmundry, Bokaro Steel City, Kolkata, Durgapur, Indore, Pithampur, Dibrugarh, Noida, Kannur, Salem, Sivakasi, Kanpur, Rajkot, Kochi, Peenya, Surat, Chhattisgarh, Madhya Pradesh, Andhra Pradesh, Jharkhand, Bihar, West Bengal, Assam, Kerala, Gujarat

Why to choose ITC?

We, ITC India providing service to the client from the last 8 years with 100 % satisfied clients. Being NABL accredited, it is equipped with highly accurate machines, experienced and competent engineers. Customer satisfaction is the quality policy of the company. So, we are here to serve the clients in their testing requirements.
  1. Reasonable Price: Very competitive price, being one of the best on the market. Moreover, this price has no hidden fees.
  1. The quality of our support is unmatched: We take support one step further by tailoring our replies to suit your knowledge, expectations and personality.
  1. We’re passionate about what we do: What sets us apart from the competition is that we’re passionate about the services we provide and quality of support.
  1. Proven track record: We’ve gained a reputation as a reliable and honest company in the last 7 years with most of our customers coming from reference.

If Your Buyers Demanding for Fence Energizer Testing  – Contact Now!

Kindly send us the following Details, So that we can provide you quotation for the same:

  1. Product Name, Technical Specifications and Brochure
  2. Product Images
  3. Total Number of samples Required: 2

ITC India has around 5000 clients from Fence Energizer division from All over India.

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Submit Your Request For FREE Sample Test Report!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:


Monday, 10 April 2017

Q:-Current of magnitude 1 milliamp flowing through the body can lead to:

 1. Just a faint tingle
 2. Sudden Death
 3. Slight shock
 4. Painful shock

Monday, 3 April 2017

Q:- Tarapur Nuclear Power Plant has Which Type of Reactor?

1. Pressurized Water Reactors 
2. Boiling Water Type 
3. CANDU Type Reactors 
4. None of Above

Hints: 
The Tarapur nuclear power plant has initially built with two boiling water reactors with the capacity of 210 MW on 1969.but,now this plant has built extra.two pressurized heavy water reactor with the capacity of 540MW on 2006

Monday, 27 March 2017

Q:- What is the value of demand factor?

1. Greater than unity. 
2. Less than unity. 
3. Always more than unity. 
4. Normally more than unity.

Wednesday, 22 March 2017

Why Do Exporters Need RoHS Certificate?

Why Do Exporters Need RoHS Certificate?


Why Do Exporters Need RoHS Certificate?

Directive 2011/65/EC imposes a mandatory requirement that any person that sells electrical or electronic products, sub-assemblies or components directly to RoHS countries, or sells to re sellers, distributors or integrator s that in turn sell products to these countries, is bound to pass RoHS compliance. Their product will not be allowed in EU market if they utilize any of the restricted materials.
The RoHS certificate issue by Eurotech certifies and confirms that the evaluation of the product has been done as per the directive 2011/65/EU and that the product is RoHS compliance. Exporter and manufacturer can use this certificate in EU whenever asked for RoHS compliance.

If you’re Buyers Demanding for RoHs Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:


Monday, 20 March 2017

What is RoHS Compliance?


What is RoHS compliance?

What is RoHS Compliance?

RoHS or the directive 2011/65/EC restrict the use of hazardous substances in electrical & electronic products .As per the directive all the electrical & electronic products which are placed in EU market must be RoHS complaint i.e they either should not contain these restricted material or the quantity present must be under acceptable limits.
The substances banned under RoHS are lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (CrVI), polybrominated biphenyls (PBB), polybrominated diphenyl ethers (PBDE), and four different phthalates (DEHP, BBP, BBP, DIBP).

If you’re Buyers Demanding for RoHs Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:


Q:- In India highest kV is..

A. 960 
B. 765 
C. 220 
D. 758 

Monday, 6 March 2017

Monday, 27 February 2017

Monday, 13 February 2017

Q:- Which Motor is Used in Electric Traction?

A. Synchronous motor. 
B. DC series motor. 
C. Reluctance motor. 
D. Induction motor.

Sunday, 5 February 2017

Q:- Temporary magnets are used in which of the following?

1. Loud speakers. 
2. Generators. 
3. Motors. 
4. All of these. 

Hints :- 
Permanent magnets lose their power after some days. So, if we use permanent magnet in those equipment, then it does not give efficient output. But, the above mentioned equipment's have to work efficiently at all time. That is why the temporary magnets (or) the electromagnets are used in the above mentioned machines.

Wednesday, 11 January 2017

Tuesday, 4 October 2016

Photometry Testing Equipments

Photometry Testing Equipments

ITC India Pvt Ltd offers an extensive photometric testing service that is mentioned below. We provide the reports with NABL logo. As far as our scope, we cover all the solid state lightning luminaries. Our aim is to provide you with accurate, concise and relevant reliable information.

Now, the question arises, what the equipment's necessary for Photometric are testing. To measure colorimetric parameters, electrical parameters, photometric parameters, an integrating sphere is required. The function of an integrating sphere is to spatially integrate radiant flux. The design of an integrating sphere for any application involves a few basic parameters. These include selecting the optimum sphere diameter based upon the number and size of port openings and peripheral devices. Selecting the proper sphere coating considers spectral range, as well as performance requirements. When choosing a coating for an integrating sphere two factors must be taken into account: reflectance and durability. Integrating spheres collect the total flux emitted from a lamp, because an integrating sphere reflects and integrates all the light entering the sphere, the light received by a small area of the sphere is directly proportional to the total flux from a light source mounted within the sphere. The total flux from a test lamp is determined by comparing it to a calibrated working standard. The integrating sphere must include a lamp socket fixture, baffles, and a viewing port for the photo detector. In high accuracy measurements, an auxiliary lamp may be used to correct for lamp self absorption.
integrating sphere for lm-79-testing

Integrating Sphere

For Light Intensity Distribution, a Goniophotometer is required. ITC owns a moving detector goniophotometer with class 1 accuracy. According to LM-79 clause 9.3.1, only two kind of type C goinophotometer can be accepted, moving detector goinophotometer and goniophotometer with moving mirror. It can measure all types of lightning sources, LED or HID luminaries such as indoor and outdoor luminaries, roadways luminaries, street lamps, flood lights and other kinds of luminaries.
goniophotometer-for-photometry-testing

Goniophotometer

It can measure
  • Luminous intensity data
  • Luminous intensity distribution
  • Zonal luminous flux
  • Luminaries Efficiency
  • Coefficient of Utilization
  • Luminance limitation curves
  • Glare
  • Maximum Ratio of distance to height
  • Equal illuminance diagrams
  • Isocandela diagrams
  • Efficient luminescence angle
For any kind of query regarding LM 79 or photometry testing

If you’re Buyers Demanding for Photometry Testing– Contact Now!

ITC India has around 5000 clients from LED lighting division from All over India.

If you are interested to Get Photometry Test Report, You can Please feel free to Ask for Quotation.

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:


Submit your requirement for Testing:-
Full Name


E-mail:


Describe Your Requirements with Technical Details:






Monday, 22 August 2016

LM-79 Testing

Electrical Safety Testing Lab ITC India: LED Lighting & LM-79 Luminaire Testing Laboratory ...: We, ITC India, are a leading testing company/laboratory having a NABL (Certificate No. T 1811) accreditation. The Laboratory is following ...

LM-79 Testing
If you are looking for LM-79 Testing service in your Area, you can feel free to contact us.
Puneet Sharma |M: +91.8196980555 |E-mail:- itcindiaone@gmail.com


Submit your requirement for Testing:-
Full Name


E-mail:


Describe Your Requirements with Technical Details:







Wednesday, 10 August 2016

IP testing as per IEC 60529 | Ingress Protection Laboratory

Ingress Protection Testing, IP testing as per IEC 60529, Ingress Protection Laboratory

ITC India NABL Accredited state of the art testing services for IP (Ingress Protection) Testing along with our technical expertise will ensure complete Client satisfaction.ITC India have marketing offices in Kolkata, Mumbai, Ahmedabad, Chennai, New Delhi, Chandigarh, Panchkula, Mohali, Bangalore, Hyderabad, Pune, Surat, Visakhapatnam, Indore, Bhubaneshwar, Coimbatore, Nagpur, Kochi, Mangalore, Vadodara, Jaipur, Kozhikode (Calicut), Noida, Gurgaon, Navi Mumbai, Lucknow, Patna


ITC India carry out (Ingress protection) IP testing as per the requirements of IEC 60529 for protection against solid foreign objects and/ liquids, depending on the requirements of the Client.

If you are looking for IP Testing laboratory in India, ITC India NABL Accredited Electrical Safety Testing Laboratory under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 & T-1811. ITC India Laboratory is fully equipped with high accuracy Measuring Instruments and trained personnel to provide testing and certification Services for Electrical and Electronic equipments. ITC Lab is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.

Degrees for protection for electrical enclosures
IEC:60529, IS:12063, IS:60947 (P-1) 2004
Luminaries is: 10322
Rotating machinery is: 4691, IEC:60034 -5
Environmental protection tests
ITC India have developed a special testing facility against Solid particle protection and Liquid ingress protection generally called as the IP testing. We have below test facility at present in our, We cover the range of protection types: IP XX as below:

1. IP 1X, IP 2X, IP 4X for protection of machine against Penetration by solid foreign objects
2. IP 5X for Dust Protection
3. IP 6X for Dust Protection
4. IP X7, IP X8, IP X5 & IP X6 for protection against ingress of water.

Dust chamber

DUST CHAMBER

Splash rain test

SPLASH RAIN TEST

3 to 5mm of rain precipitation rate simulation equipment for ipx1 and ipx2 tests

3 TO 5mm OF RAIN PRECIPITATION RATE SIMULATION EQUIPMENT FOR IPX1 AND IPX2 TESTS
Water spray tests
Water spray tests

Top Searches related to ip testing:

ip address testing                                     ip testing procedure
ip testing equipment                               ip testing labs
proxy testing                                              ip speed test

If you’re Buyers Demanding for IP Testing– Contact Now!

ITC India has around 5000 clients from LED lighting division from All over India.

Get IP Test Report, You can Please feel free to Ask for Quotation.

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:

Submit your requirement for Testing:-
Full Name


E-mail:


Describe Your Requirements with Technical Details:


Friday, 5 August 2016

lm-79 Testing | lm 79 test report | lm 79 test procedure

LM-79 Testing, Lm 79 Test report, LM 79 Test procedure, India

ITC India is a NABL accredited laboratory in discipline of Electrical (T-1811), Electronics (T-3509) and photometry (T-3510), serving its satisfied customers for last 5 years. Laboratory is fully equipped with the highly accurate Machines to test LM 79. It owns a Integrating sphere as well as the Goniophotometer.  Qualified and experienced engineer are appointed to perform the desired tests.
Gone are those days when we use incandescence (tungsten filament) or fluorescent (mercury atoms) bulb. They are replaced by LED’s Now; this is an era of SSL (LED) as ……There is innumerable reason for the rise in LED’s which cannot be counted on finger tips. It is beneficial to both USERS as well as to the nation. Its superior features make it so promising that one cannot deny using LED’s.  The features of LED’s are, its low power consumption, digitally controllable,   Low maintenance, Ultra long source life, no UV or IR radiations, No mercury content. SSL uses semiconductors material to convert Electricity into light.  LED’s are non carbon materials.
Efficacy is the quality parameter for LED: it is measure in Lumen per watt. Higher efficacy means high energy efficient. Another quality factor is lifetime and last but not the least is Color rendering Index (CRI). CRI measures the ability of light source to reproduce the color of various objects in comparison with natural light source.

How LM-79 testing can help assess LED luminaries quality and performance?

AS LM79 report provides you with the Photometric as well as electrical parameters with a spectrum Test report. The photometric parameters are luminous flux, Efficacy and Radiant Power, CIE colorimetric Parameters (coordinates Color rendering Index (CRI), color coordinate Temperature (CCT) Duv Value, and light Intensity Distribution .Current, Voltage, Power factor, Power and frequency are the electrical parameters. It Focus on the efficiency and CRI, which are the quality parameter. Efficiency measures how much electrical energy is converting into light energy. Power factor is another electrical metric for LED driver performance and often a key parameter for street lighting due to the large number of these luminaries connected to the power grid.  As far as for lifetime, LM 80 covers that part.

What is the LM-79 test methodology?

 LM 79 is approved method to test Photometric and electrical measurements of Solid state lightning. It describes the procedure and precaution to be observed during measurements. This approved method covers LED based SSL products with control electronics and heat sinks incorporated, that is , those devices that require only AC main power or a DC voltage power supply to operate. This document does not covers SSL products that require external operating circuits, or external heat sink. LM 79 covers SSL product in a form of luminaries (fixture incorporating light source) as well as integrated LED lamps.

Why do we need it?

We need it to access the quality and other parameters due to increasing competition in the market. It provides the efficiency and power factor.   

How is LM-79 different from other test methods used for conventional lighting products?

This approved method is a guide developed for the measurements of SSL products. While many other standards for photometric measurements of light sources and luminaries are available, these standards are separated for measurements of lamps and luminaries. Since the current SSL products are in the form of luminaries or lamps, and LED light source in luminaries are not easily separated as replaceable lamps, these existing standard cannot be applied directly to SSL products. This necessitates the use of absolute photometry. This test method uses absolute photometry where as other standard uses relative photometry in short.

Now lets us clear about relative and absolute photometry.

S.NOAbsolute PhotometryRelative Photometry
1Total lumen output of a luminary (bulb with fixture)Total Lumen output of a bare lamp is measured.
2Method used to measure LED performance.Method used to measure Bare bulb and system performance.
3Output is relative to an easy measured condition.

Output is measured in calibrated units under specific operating and environment conditions, ambient temperature, input voltage and orientation.
4Specific lamp performance does not matter,

Lamps and system performance matters.

5Use for SSL productsFor NON SSL products

What are the LM-79 test outcomes?

The outcome of the LM 79 is the REPORT providing all the required parameters as per LM 79.
They are ……
  1. CIE colorimetric parameters
  2. Chromaticity coordinate (x)
  3. Chromaticity coordinate (y)
  4. Chromaticity coordinate (u’)
  5. Chromaticity coordinate (v)
  6. Chromaticity coordinate (v’)
  7. Correlated color temperature(Tc)
  8. Duv Value
  9. Color Rendering Index(Ra)
  10. Photometric Parameters
  11. Luminous Flux( Lumen)
  12. Luminous Efficacy( Lm/W)
  13. Radiant Power
  14. Electric Parameters
  15. Input Voltage(V)
  16. Current(A)
  17. Power(W)
  18. Power Factor
  19. Frequency(Hz)
  20. Test information
Ambient Temperature, Stabilization Time, Total Operating Time, Sphere Dia, Photometric method or instrument used Wavelength range in nm of spectroradiometer.
Along with this a SPECTRUM TEST REPORT is also issued.

What are the limitations of LM-79?

  • Chips, Packages, or Modules requiring external heat sinks or operating circuits are not covered
  • Does not state the sampling size.

Is there a future scope for improvement in the LM-79 test?

Yes of course, there is always a scope for improvement in all areas.
Range/criteria of acceptance of CCT, CRI & Lumens may be defining to establish a harmonization of parameters globally.

Top Searches related to LM 79 Tests for LED Tube Lights:

lm 79 standard                                           lm-80
lm 79 test report                                        lm79 and lm80 standards
lm-79 test procedure                            lm 79 testing labs in india
ies lm-80                                                   lm 79 80 standards
LM-79 Testing Report                          LM-79 Testing Service in India

 

If you’re Buyers Demanding for LM-79 Testing– Contact Now!

ITC India has around 5000 clients from LED lighting division from All over India.

Get LM 79 Test Report, You can Please feel free to Ask for Quotation.

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:

Submit your requirement for Testing:-
Full Name


E-mail:


Describe Your Requirements with Technical Details: