We have BIS and NABL Accredited Electrical Safety Testing Electrical Safety Testing Laboratory. Mr.Puneet Sharma Call 08196980555 E-mail: Itcindiaone@gmail.com
Sunday, 16 December 2018
Friday, 14 December 2018
How To Get IP66 Testing And Certification In India?
How To Get IP66 Testing And Certification In India? |
IP66 Ingress Protection Testing And Certification
Are you looking for IP66 Testing and Certification Laboratory in India, If yes then you are at the right website We are One of the Best IP66 Testing and Certification Lab in India, Let's introduced with the place which is Best for IP66 Testing And Certification Labs where you can have the best result for IP66 Testing. Call on 08196980555 for IP66 Testing laboratories.
IP66 Testing Labs offers a full range of IP66 Testing services. We have fully equipped to test and approve a wide range of electrical products and equipment for organizational and governmental certifications, from battery chargers and lighting equipment to medical electrical equipment and wireless devices.
IP66 Enclosure - IP rated as "dust tight" and protected against heavy seas or powerful jets of water.
IP66 Defining Characteristics:
- Complete protection from dust, oil, and other non-corrosive material
- Complete protection from contact with the enclosed equipment
- Protection from water, even from powerful jets of water
- Equivalent to NEMA rated 4 and 4X enclosures
- Engraving, silk-screening, and anodizing services available
- Custom with cutouts, insulation, hinges, latches, or locks
IP66 Protection Standards
http://www.youtube.com/watch?v=UqqBvBSZMnQRefer to the chart below for the ratings of relative protection of electrical enclosures:
IP Rating | Protection | Description | Test Method |
IP66 Enclosures | Able to protect against powerful water jets | Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects. | Test duration: at least 3 minutes |
Water volume: 100 liters per minute | |||
Pressure: 100 kPa at a distance of 3 m | |||
IP66 Protected from total dust ingress. Protected from high-pressure water jets from any direction. IP66 Rating / IP66 Certification: The first digit (6) & the second digit (6) both are described above
For enclosures, the typical waterproof IP ratings are IP66 enclosures. The chart below gives the specifics of what these ratings mean and how they are measured.
For enclosures, the typical waterproof IP ratings are IP66 enclosures. The chart below gives the specifics of what these ratings mean and how they are measured.
What is the meaning of ip66?
IP65 Enclosure - IP rated as "dust tight" and protected against water projected from a nozzle. IP66 Enclosure - IP rated as "dust tight" and protected against heavy seas or powerful jets of water. IP 67 Enclosures - IP rated as "dust tight" and protected against immersion. learn more
What does ip66 waterproof mean?
If you want to light your outdoor area, one solution that may cross your mind is the installation of a light-emitting diode (lighting) lamp. ... Such lights normally have IP65 or IP66 ratings. However, the latter has a more robust waterproof capability, but it is paramount to know what “IP66” means. Learn More
IP66 WATER
1. Protected against vertically falling drops of water. Limited ingress permitted.
2. Protected against vertically falling drops of water with enclosure tilted up to 15 degrees from the vertical. Limited ingress permitted.
3 Protected against sprays of water up to 60 degrees from the vertical. Limited ingress permitted for three minutes.
4. Protected against water splashed in all directions. Limited ingress permitted.
5. Protected against jets of water. Limited ingress permitted.
6. Water from heavy seas or water projected in powerful jets shall not enter the enclosure in harmful quantities.
7. Protection against the effects of immersion in water between 15 cm and 1 m for 30 minutes.
8. Protection against the effects of immersion in water under pressure for long periods.
2. Protected against vertically falling drops of water with enclosure tilted up to 15 degrees from the vertical. Limited ingress permitted.
3 Protected against sprays of water up to 60 degrees from the vertical. Limited ingress permitted for three minutes.
4. Protected against water splashed in all directions. Limited ingress permitted.
5. Protected against jets of water. Limited ingress permitted.
6. Water from heavy seas or water projected in powerful jets shall not enter the enclosure in harmful quantities.
7. Protection against the effects of immersion in water between 15 cm and 1 m for 30 minutes.
8. Protection against the effects of immersion in water under pressure for long periods.
IP66 SOLIDS
1. Protected against a solid object greater than 50 mm 4pr A-.1 such as a hand.
2. Protected against a solid object greater than 12.5 mm such as a finger.
3. Protected against a solid object greater than 2.5 mm such as a screwdriver.
4. Protected against a solid object greater than 1 mm such as a wire.
5. Dust Protected. Limited ingress of dust permitted. Will not interfere with the operation of the equipment. Two to eight hours.
6. Dust-tight. No Ingress of dust. Two to eight hours.
2. Protected against a solid object greater than 12.5 mm such as a finger.
3. Protected against a solid object greater than 2.5 mm such as a screwdriver.
4. Protected against a solid object greater than 1 mm such as a wire.
5. Dust Protected. Limited ingress of dust permitted. Will not interfere with the operation of the equipment. Two to eight hours.
6. Dust-tight. No Ingress of dust. Two to eight hours.
Why Choose Us For IP65 Testing?
We are a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state-of-the-art testing laboratories, assure a single-source solution for meeting all applicable requirements, standards, and voluntary schemes. And technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up-to-date knowledge of current and changing requirements.
Represented in over 5 locations in India, We have an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.
We can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance
If Your Buyers Demanding for IP Testing – Contact Now!
Kindly send us the following Details, So that we can provide you with a quotation for the same:
- Product Name, Technical Specifications, and Brochure
- Product Images
- Total Number of Samples Required: 2
Wish this blog post will help. If you have any other questions, please feel free to contact us. Our team looking forward to working with you and get better together!
Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com
Get Instant Quotations, Fill the Enquiry form:
Location:
India
Wednesday, 5 December 2018
How To Get IP65 Testing And Certification In India?
How To Get IP65 Testing And Certification In India? |
How To Get IP65 Testing And Certification In India?
Are you looking for IP65 Testing and Certification Laboratory in India, If yes then you are at the right website We are One of the Best IP65 Testing and Certification Lab in India, Let's introduced with the place which is best for IP65 Testing And Certification Labs where you can have the best result for IP65 Testing. Call on 08196980555 for IP65 Testing laboratories.
IP65 Testing Labs offers a full range of IP65 Testing services. We have fully equipped to test and approve a wide range of electrical products and equipment for organizational and governmental certifications, from battery chargers and lighting equipment to medical electrical equipment and wireless devices.
IP65 Testing And certification
IP65 Rating / IP65 Certification: The first digit 6 shows complete protection against contact with live or moving parts inside the enclosure and against the ingress of dust. Meaning of second digit 5 already described above.
IP Enclosure Ratings and Standards Explained
The IP rating is also known as Ingress Protection or International Protection ratings which are defined to the international standard of EN 60529, BS EN 60529:1992, IEC 60509:1989. These standards are used to define the levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies such as dirt and water.
The rating consists of the letters IP followed by 2 digits, the first digit stands for the level of protection that the enclosure provides against solid bodies, the second digit describes the degree of protection of the equipment inside the enclosure against water.
IP65 = First Digit - Solids
IP65 = Second Digit - Liquids
Below is easy to follow chart to help you decide which IP rating / IP Codes you may require for your electrical enclosure, Rainford manufacturers IP rated electrical enclosures including IP54, IP65 up to IP
What is an ip65 enclosure?
IP65 Enclosure - IP rated as "dust tight" and protected against water projected from a nozzle. IP66 Enclosure - IP rated as "dust tight" and protected against heavy seas or powerful jets of water. IP 67 Enclosures - IP rated as "dust tight" and protected against immersion. Learn More
Is ip65 waterproof?
Example: With an IP65 rating, the LEDs can be used in an outside setting and are water-resistant but they are not waterproof and are not suitable to be submerged. An IP68 can be submerged in water. Learn more
What are ip65 standards?
we utilize the IEC's standardized International Protection Code system for measuring enclosures' capabilities. The IP Code reflects the degree of protection as "IP" followed by two numbers; the first digit shows the extent to which enclosures are protected against particles and protection to others from enclosed hazards. The second digit indicates the extent of protection against water. We carry IP65 enclosures which offer complete protection against particles, and a good level of protection against water. Because all of our enclosures strictly observe the standards, you can expect first-rate and competitively-priced enclosures.
IP65 Enclosures' Characteristics:
- Complete protection from dust, oil, and other non-corrosive material
- Complete protection from contact with the enclosed equipment
- Protection from water, up to water projected by a nozzle against enclosure from any direction
- Silk-screening, anodizing, or engraving services available
- Custom with cutouts, insulation, hinges, latches, or locks
IP 65 Standards for Electrical Enclosure Protection
Refer to the chart below for the ratings of relative protection of electrical enclosures: Learn More
Refer to the chart below for the ratings of relative protection of electrical enclosures: Learn More
Is ip65 suitable for outdoor use?
Waterproof Wall Lights for Outdoor Lighting. There is a wide range of wall lights, but not all can be used outdoors; it is recommended to install a wall fitting that is at least IP44 rated so that water would not reach the electricals, or even an IP65 or IP67 waterproof fitting (to be more secure) Learn More
IP Testing Procedure
IP Testing (IEC 60529): IEC 60529 is an international standard designed to give products a determined International Protection Marking according to the IP Code rating. This standard tests the sealing effectiveness of enclosures of electrical equipment against the intrusion of solid particles and liquid. Learn more
Water Resistant and Waterproofing Testing And Certification as Per IP65
We offer waterproof testing along with hundreds of other environmental testing services. Our lab experts are experienced in many industry standards including ISO 20653 and EN/IEC 60529 which outline the procedures and ratings for ingress protection testing. We assist many manufacturers and product developers in qualifying and certifying component durability.
We Can do IP65 Testing And Certification on Common Products That Are Waterproof
- LED Lights
- Watches
- Laptops
- Phones
- Tablets
- Automotive Components
- Scuba Gear
- Gauges
- Cameras
- Radios
- Speakers
- Boots
- Laugage
- Gloves
- Electronic Components
- Military Components
Why choose Us For IP65 Testing?
We are a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state-of-the-art testing laboratories, assure a single-source solution for meeting all applicable requirements, standards, and voluntary schemes. And technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up-to-date knowledge of current and changing requirements.
Represented in over 5 locations in India, We have an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.
We can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance
If Your Buyers Demanding for IP65 Testing – Contact Now!
Kindly send us the following Details, So that we can provide you with a quotation for the same:
- Product Name, Technical Specifications, and Brochure
- Product Images
- Total Number of Samples Required: 2
Wish this blog post will help. If you have any other questions, please feel free to contact us. Our team looking forward to working with you and get better together!
Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com
Get Instant Quotations, Fill the Enquiry form:
Location:
India
Monday, 3 December 2018
EN-IEC 60601 Testing Laboratories in India
EN-IEC 60601 Testing Laboratories in India |
EN/IEC 60601 Testing Laboratories in India
let Introduced with the place which is best for IEC 60601 Testing Labs where you can have the best result for 60601 Testing. Call on 08196980555 for 60601 Testing laboratories
We are one of the Best 60601 Testing laboratories for medical devices to verify compliance with major standards and international regulations.
EN/IEC 60601 Testing Labs offers a full range of EN/IEC 60601 Testing services. We have fully equipped to test and approve a wide range of electrical products and equipment for organizational and governmental certifications, from battery chargers and lighting equipment to medical electrical equipment and wireless devices.
The medical industry is rapidly adopting new technology that enables better communication and performance of Equipment and systems to improve the safety of care. Manufacturers today, face a number of compliance challenges, as devices that do not meet the highest quality and safety standards present, a risk of injury, recalls, bans and liability.
Electronic devices used in medical environments have important safety and performance requirements to ensure safety and compatibility with other critical care product.
Complying with EN/IEC 60601-1 Standard
EN/IEC 60601-1 applies to all Medical Electrical products and Medical Electrical Systems. The medical Electrical product is defined in the standard as electrical equipment having an applied part or transferring energy to or from the patient or detecting such energy transfer to or from the patient and which is:
- Provided with not more than one connection to a particular supply main and
- Intended by its manufacturer to be used in the diagnosis, treatment, or monitoring of a patient; or for compensation or alleviation of disease, injury or disability.
- This includes a wide range of medical devices, for example:
- High-Frequency Surgical Equipment
- Cardiac Defibrillators
- Patient Monitors
- Therapeutic and Diagnostic Ultrasound Equipment
- Medical Lasers
- Patient Ventilators
- Infant Incubators and Warmers
EN/IEC 60601-1 for Medical Electrical Equipment Safety Testing
EN/IEC 60601-1 is the harmonized standard for medical electrical equipment recognized by public health authorities in most countries. In addition to basic safety requirements, the third edition with amendment 1 includes requirements for essential performance, software, usability, lasers and EMC that can be delivered locally via our own test labs where customers can witness their tests.
Our services for EN/IEC 60601 based standards
- The option of using the question-based approach or an on-site audit-based approach to demonstrate conformity to EN/IEC 60601-1:2005
- Public and private training to IEC 60601 2nd and 3rd editions, differences, ISO 14971, Amendment 1, and more
- Gap assessment to EN/IEC 60601 and ISO 14971
- IEC 60601 Proactive Review – Early engagement for both 2nd and 3rd edition to support demanding project completion schedules.
- Options for evaluations to EN/IEC 60601 2nd and 3rd editions
- Potential for reduced FUS inspections and integrated quality system ISO 13485 and/or ISO 14971 assessments
- CB Scheme test reports and test certificates
- Software assessments to support EN/IEC 60601 Clause 14 and, if requested, EN/IEC 62304
- Usability assessments to support Collateral standard EN/IEC 60601-1-6 and, if requested, EN/IEC 62366
- EMC testing and assessments to support EN/IEC 60601-1-2
- Home Healthcare assessments to support EN/IEC 60601-1-11
Top 15 Easy Way To Get test Report as per EN/IEC 60601
- Prepare A Project Plan
- Determine Which Standards Apply To Your Device
- Classify Your Product
- Create An Isolation Diagram Early In The Development Lifecycle
- Identify Critical Components And Obtain Manufacturer Specification Sheets
- Identify Essential Performance And Prepare A Draft Rmf
- Draft Your Test Plan
- Review Marking And Labeling Requirements
- Construction Review
- What To Consider With Test Labs
- Request Quotes
- Finalize Rmf And Essential Performance
- Pre-test Your Device(S)
- Determine What You Need For Testing And Critical Timelines
- Communication With Test Labs And End Results
Top 7 Benefits of EN/IEC 60601 Testing :
With EN/IEC 60601-1 compliance testing from us, you can be sure of:
- A worldwide benchmark for electrical medical equipment
- Conformity to approved standards worldwide
- Position your products competitively worldwide with an independent third-party test mark
- Reduced risk of company liability with documented safety standards
- Fast audit times and long-standing experience from a company with a global presence
- Our exclusive, one-stop service
- Compliance with local government and legal requirements
Our Advantages of using EN/IEC 60601 Testing Labs
- 24-hour start for critical projects
- Real-time online project tracking
- Extensive knowledge of FDA requirements and procedures
- Less than one hour drive from FDA headquarters, for conducting face-to-face meetings and helping to expedite a clearance
People also ask
- What is the IEC 60601 1 standard?
- What is 60601?
- What is medical electrical equipment?
- What is an essential performance?
Our thorough knowledge of industry performance and national safety standards, combined with extensive global testing resources, allows you to get your equipment on the market in a timely and cost-effective way.
Why Choose Us For LED Testing?
We are a leading provider of comprehensive testing services for Medical products. Our global network of technical experts, combined with our state-of-the-art testing laboratories, assure a single-source solution for meeting all applicable requirements, standards, and voluntary schemes. And technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up-to-date knowledge of current and changing requirements.
Represented in over 5 locations in India, We have an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.
We can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance
If Your Buyers Demanding for 60601 Testing – Contact Now!
Kindly send us the following Details, So that we can provide you with a quotation for the same:
- Product Name, Technical Specifications, and Brochure
- Product Images
- Total Number of Samples Required: 2
Wish this blog post will help. If you have any other questions, please feel free to contact us. Our team looking forward to working with you and get better together!
Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com
Location:
India
LED Testing Laboratories – LED Testing Lab Near Me
LED Testing Labs | LED Testing Laboratories – LED Testing Lab Near Me |
LED Testing Lab, LED Testing, LED Testing laboratories, LED Testing Labs, LED Test Lab
ITC India is having best LED Testing Labs to test LED. We provide all types of testing related to LED Lights. Call at 08196980555 for LED Testing Laboratories.
ITC India test Laboratories provides LED Testing Lab to help customer product development. ITC India has fully equipped LED Testing Lab where we allow customers to characterize LEDs, light engines, and SSL lamps, luminaries and modules etc. We are offering one-stop shopping quality to each customer through our expertise, and state of the art product testing facilities.
Supporting your testing and certification requirements for LED lighting
Significant improvements in the quality and performance of light emitting diodes LED lighting has made it the preferred technology for lamps and lighting products used in consumer, commercial and industrial applications. LED lighting is more energy efficient, and the rapidly growing use of LED lighting will help to reduce energy demand in the coming years. However, LED technology continues to evolve to meet the performance requirements of more demanding applications. As a result, LED testing requirements are changing and expanding to address these issues.
We support the LED industry in the following area:
- General Testing of LED Arrays, Lamps, Luminaires, Lighting Systems LED Modules and so on
- General Testing of Lighting parts and components
- Product Improvement and Engineering Excellence Solutions
- Quality Assurance and Sourcing Excellence Solutions
What is LED Testing?
Like other lighting products, LED lighting is typically subject to electrical safety, electromagnetic compatibility, and energy efficiency testing. In addition, product performance issues related to the color and intensity of emitted light or exposure to extreme environmental conditions are important considerations for LED lighting products used in demanding applications such as transportation and infrastructure projects. Concerns about the possible health effects from exposure to light generated from LED lighting has also resulted in the introduction of photobiological testing of LED lighting to ensure user safety.
ITC India supports companies from basic research like LED lighting module performance by fully accredited testing in conjunction and pre-compliance testing with our certification partners like EUROTECH, EUROCERT, EUROINSPECTIONS and NABCBL to international standards and performance schemes such as Lighting Facts, DLC , CEC, Eco Design, Lighting Facts, Energy Labeling and safety schemes like ENEC, CE, GS and UL/ETL Marks. If you are looking LED testing lab then choose ITC India LED Testing Laboratories which is India’s trusted Laboratories.
Searches related to LED Testing Labs
Why LED testing is Important?
LED lighting performance is a primary concern for commercial and industrial customers, and certification to specific performance standards can be used as evidence of compliance with buyer requirements. In addition, demonstrated compliance with the requirements of voluntary energy efficiency schemes, such as the U.S. ENERGY STAR program, can be important factors for marketplace acceptance. Finally, certain tests such as those addressing electrical and photometric safety are generally required for access to major markets, including the U.S. and the EU.
ITC India Can do Photometric Performance Information as per IES Standards:
ITCIndia can provide various services to measure the photometric performance of LED packages, lamps, luminaires and other light sources and products.
ITC India NABL And BIS accredited Photometric laboratory can do:
ITC India Can do Color Measurements as per IES Standards:
- IES LM-58:1994- Spectroradiometric Measurements
- CIE Pub. 13.3:1995- Method of Measuring and Specifying Color Rendering of Light Sources
ITC India Can do Luminaires Testing as per IES Standards:
- IES LM-10:1996- Photometric Testing of Outdoor Fluorescent Luminaires
- IES LM-31:1995- Photometric Testing of Roadway Luminaires
- IES LM-35:2002- Photometric Testing of Floodlights Using Incandescent Filament or Discharge Lamps
- IES LM-41:1998- Photometric Testing of Indoor Fluorescent Luminaires
- IES LM-46:2004- Photometric Testing of Indoor Luminaires Using High-Intensity Discharge or Incandescent Filament Lamps
LED Lights cannot be manufactured with consistent optical properties as a result of the production processes involved. Brightness and color can vary substantially from component to component even in the same production batch. This is why LED Lights have to be tested during production and in their final application. Comprehensive optical characterization is also essential during research and development of LED Lights and for LED Lights -based products.
ITCIndia services for LED Lights include the following tests and certifications:
- IEC/EN 62471 photobiological safety of lamps and lamp systems
- IEC/EN 62031 safety requirement of LED module for general lighting
- IEC/EN 60968 safety requirement of the self-ballasted lamp for general lighting
- IEC 62560 safety requirement of LED self-ballasted lamp for general lighting which goes beyond 50V
- IEC/EN 61347-1 safety requirement and general usage of lamp control gear-part1
- IEC/EN 61347-2-13 lamp control gear-part 2-13: the special requirement of LED module that uses alternating or direct current electronic control gear
- IEC/EN 60598 the safety requirement of various light fixtures
- IEC/EN 60838-2-2 miscellaneous lamp sockets-part 2-2: the special requirements of LED module connectors
ITCIndia has developed turnkey solutions for determining luminous intensity, luminous flux, color, spectrum and spatial radiation pattern of LED Lights. The measurement systems generate very accurate results with reliable reproducibility in conformity with the guidelines of the CIE 127 document of the International Commission on Illumination. Instrument Systems uses high-performance spectroradiometers to deliver these solutions.
ITC India Can do Photometric Measurements per IES Standards:
- IES LM-9:1999- Fluorescent Lamps - Total Flux Measurements
- IES LM-9:1999- Fluorescent Lamps - Intensity Measurements
- IES LM-9:2009- Fluorescent Lamps - Total Flux Measurements
- IES LM-9:2009- Fluorescent Lamps - Intensity Measurements
- IES LM-45:1991- Incandescent Lamps - Intensity Measurements
- IES LM-45:2000- Incandescent Lamps - Total Flux Measurements
- IES LM-45:2000- Incandescent Lamps - Intensity Measurements
- IES LM-45:2009- Incandescent Lamps - Total Flux Measurements
- IES LM-45:2009- Incandescent Lamps - Intensity Measurements
- IES LM-51:2000- High-Intensity Discharge Lamps -Total Flux Measurements
- IES LM-51:2000- High-Intensity Discharge Lamps - Intensity Measurements
- IES LM-66:2000- Single-Ended Compact Fluorescent Lamps - Total Flux Measurements
- IES LM-66:2000- Single-Ended Compact Fluorescent Lamps - Intensity Measurements
- IES LM-66:2011- Single-Ended Compact Fluorescent Lamps - Total Flux Measurements
- IES LM-66:2011- Single-Ended Compact Fluorescent Lamps - Intensity Measurements
- EN/IEC 60969, Ed. 1.2: 2001- Self-Ballasted Lamps for General Lighting Services - Performance Requirements
ITC India Can do SSL Color Measurements per IES Standards
- IES LM-58:1994- Spectroradiometric Measurements
- CIE Pub. 13.3:1995- Method of Measuring and Specifying Color Rendering of Light Sources
- IES LM-79:2008 - Solid State Lighting Luminaires - Color Characteristic Measurements
- IES LM-16:1993- Practical Guide to Colorimetry of Light Sources
- CIE Pub. 15:2004- Method of Measuring and Specifying Color Rendering of Light Sources
ITC India Can do SSL Photometric Measurements per IES Standards
- IES LM-79:2008 Solid State Lighting Luminaires - Total Flux Measurements (Luminous Efficacy)
- IES LM-79:2008 Solid State Lighting Luminaires - Luminous Intensity Measurements
ITC India Can do Electrical Performance Information per IES Standards
ITC India Can do SSL Electrical Measurements per IES Standards:
- ANSI C82.2:2002- Ballast for Fluorescent Lamps - Methods of Measurement
- ANSI C82.77:2002- Harmonic Emission Limits - Related Power Quality Requirements for Lighting Equipment
ITC India Can do Electrical Measurements per IES Standards
- IES LM-9:1999- Fluorescent Lamps - Electrical Measurements
- IES LM-9:2009- Fluorescent Lamps - Electrical Measurements
- IES LM-45:2009- Incandescent Lamps - Electrical Measurements
- IES LM-51:2000- High-Intensity Discharge (HID) Lamps - Electrical Measurements
- IES LM-66:2000- Single-Ended Compact Fluorescent Lamps - Electrical Measurements
- IES LM-66:2011- Single-Ended Compact Fluorescent Lamps - Electrical Measurements
- ANSI C78.375:1997- Fluorescent Lamps - Electrical Measurements
- ANSI C78.389:2004- High-Intensity Discharge Lamps - Methods of Measuring Characteristics
- ANSI C78.5:2003- Compact Fluorescent Lamps - Run-up and Start-up Times
- ANSI C82.2:2002- Ballast for Fluorescent Lamps - Methods of Measurement
- ANSI C82.6:2005- Ballast for High-Intensity Discharge Lamps - Methods of Measurement
ITC India Can do Life test and Reliability Information per IES Standards
ITCIndia can provide services to measure the performance of lamps, luminaires and other light fittings and products in terms of their lifetime. These include:
ITC India Can do Life Tests per IES Standards
- IES LM-40:2001- Fluorescent Lamps - Life Test Performance
- IES LM-47:2001- High-Intensity Discharge Lamps - Life Test Performance
- IES LM-49:2001- Incandescent Filament Lamps - Life Test Performance
- IES LM-65:2001- Single-Ended Compact Fluorescent Lamps - Life Test Performance
- IES LM-65:2010- Single-Ended Compact Fluorescent Lamps - Life Test Performance
NABL And BIS accredited lumen depreciation testing for LED packages, modules and light engines to standards IESNA LM-80-08 and using IESNA TM-21
Future of LED lights:
Since the development of high-brightness blue and white LED Lights, the market for LED light has been booming. LED Lights are used in displays, illuminated advertisements, and lamps. The new light of white LED Lights is already being integrated with cars, aircraft, traffic lights, and classic architectural lighting. It's no surprise that a brilliant future has been predicted for LED Lights.
Companies like Philips, Osram, Bajaj and General Electric work round the clock to improve LED light. ITCIndia is cooperating intensively with these companies on metrology. This commitment represents an investment in the future because joining forces in this way provide information on the needs of industry when it comes to measuring LED Lights. ITCIndia also makes an important contribution to the definition of international standards. And this is one of the reasons why ITCIndia is One of the best NABL Approved LED Testing lab in India.
Why choose ITCIndia For LED Testing?
ITCIndia is a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state of the art testing laboratories, assure a single source solution for meeting all applicable requirements, standards and voluntary schemes. And ITCIndia technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up to date knowledge of current and changing requirements.
Represented in over 5 locations in India, ITCIndia has an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The ITCIndia brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.
NABL And BIS accredited performance testing for lumen depreciation of self-ballasted LED lamps, LED lamps with external ballasts and LED luminaires.
ITCIndia can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance
If Your Buyers Demanding for Street Light Testing – Contact Now!
Kindly send us the following Details, So that we can provide you with a quotation for the same:
- Product Name, Technical Specifications, and Brochure
- Product Images
- Total Number of Samples Required: 2
Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!
Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com
Get Instant Quotations, Fill the Enquiry form:
Location:
India
Friday, 30 November 2018
Wednesday, 21 November 2018
LM 79 Testing Laboratories - ITC India LED Test Laboratories
LM 79 Testing Lab, LM 79 Test Labs, LM 79 Test Laboratories, LM 79 Testing
Get introduced to the place which is Best for LM-79 Testing Labs where you can have the best result for LM-79 Testing. Call on 08196980555 for LM-79 Testing laboratories
LM 79 Testing
As the development of LED technology continues to grow and diversify, the need for consistent and standardized testing procedures for LED has become more prevalent than ever.
We have NABL and BIS Accredited testing for LM-79
We have made strides to stay current with the new testing standard LM 79 set forth by the Illuminating Engineering Society of North America. In addition, Testing is now a priority when testing our LED light systems for more reliable results.
LM 79 Testing Laboratories
LM-79 is a method approved for taking electrical and photometric measurements of SSL products. So we provide you accurate LM-79 testing by experts in a very short period of time. LM-79 covers total flux, light output, electrical power, efficacy, chromaticity, and intensity distribution. The five required metrics on the LED Lighting Facts label come from LM-79 testing Laboratories' results.
IES LM-79 Electrical and Photometric Measurements of Solid-State Lighting Products
An approved method describing procedures and precautions in performing reproducible measurements of LEDs:
- Total luminous flux
- Electrical powers
- Luminous Intensity distribution
- Efficacy (lm/watt)
- Chromaticity
What Is LM-79 Testing?
Everyone knows about it, in 2008, the Illuminating Engineering Society published LM 79, Approved Method for the Electrical and Photometric Measurements of SSL Products. LM-79 testing lab capture the performance nature of products that feature SSL, including light-emitting diode LEDs.
LM 79 Testing Scope
Applies to LED-based products incorporating control electronics and heat sinks, that is, those devices that require only AC mains power or a DC voltage power supply to operate.
Who can perform testing?
LM 79 testing should be performed by our Laboratory for the category of the product tested. Only reports from recognized laboratories are relevant. This standard is used for the Department Of Energy ENERGY STAR program qualification and lighting facts advocate program. All Our product testing is performed according to LM 79 in a NABL and BIS recognized laboratory and reports are available upon request.
Why We Use LM-79 Testing Lab?
The LM-79 testing lab provides a snapshot of performance under specified operating conditions at some point in the life of a product, usually, at the beginning of the operation, these are referred to as initial measurements. It never addresses permanent ratings, changing performance over time lumen maintenance, or LED case temperature.
The LM 79 methods are really applicable to integrated LED products, such as luminaries and replacement lamps. It is not applicable to LED packages, modules, or arrays
- LM 79 is the method for testing electrical and photometric measurements of SSL lighting products.
- LM 79 contains procedures for performing reproducible measurements of LED properties, including total flux, electrical power, efficacy, and chromaticity.
- The scope of LM 79 Testing Laboratories applied to LED products that incorporate control electronics and heat sinks. This covers complete LED luminaries and integrated LED sources. It does not include bare LED chips or LED-based products without a light source.
Absolute Photometry Basis
- LM 79 requires complete luminaire testing
- Traditionally, photometric evaluation of lighting products is based on separate tests for lamps and luminaires relative
- For solid-state lighting products, LED lamps typically cannot be separated from their luminaire because of heat effects absolute
What Is Important Aspect Of LM-79 Testing?
LM 79 testing requires complete luminaries testing on an absolute photometric basis. Typically lighting products are evaluated on a relative photometric basis, where separate tests are done for lamps luminaries. However, for SSL products the LED lamps typically cannot be separated from their luminaries. The absolute photometric testing required measures the light distribution and light intensity of the complete luminaries.
In recent times, the term LM 79 Testing laboratories have become part of our lighting lexicon and have been treated in some cases as lighting program all its own. While many lighting programs such as DLC and Energy Star reference LM 79 procedures, it is not in and of itself a lighting program with specified requirements and pass/ fails criteria.
However, the term LM 79 Testing Lab has come to generally be recognized as two distinct tests a candela distribution test with an IES file, and an integrating sphere test for a standard color CCT, CRI, Duv, chromaticity coordinates. Nevertheless, any time LM 79 is mentioned in reference to the desired testing, our staff will verify exactly what the customer requires since many measurement options are discussed in the official document.
Relative vs. Absolute Photometry
Relative testing Lamps of interest and luminaire with reference lamp are measured separately. Then the actual light distribution and intensity of the complete luminaire of interest is derived by normalization of the test data
Absolute testing The actual light distribution and intensity of the luminaire of interest are measured directly from the complete luminaire.
Why Choose Us?
We are providing service to the client for the last 8 years with 100 % satisfied clients. Being NABL accredited, it is equipped with highly accurate machines, experienced and competent engineers. Customer satisfaction is the quality policy of the company. So, we are here to serve the clients in their testing requirements.
- Reasonable Price: Very competitive price, being one of the best on the market. Moreover, this price has no hidden fees.
- The quality of our support is unmatched: We take support one step further by tailoring our replies to suit your knowledge, expectations, and personality.
- We’re passionate about what we do: What sets us apart from the competition is that we’re passionate about the services we provide and the quality of support.
- Proven track record: We’ve gained a reputation as a reliable and honest company in the last 7 years with most of our customers coming from reference.
If Your Buyers Demanding for Street Light Testing – Contact Now!
Kindly send us the following Details, So that we can provide you with a quotation for the same:
- Product Name, Technical Specifications, and Brochure
- Product Images
- Total Number of Samples Required: 2
Wish this blog post will help. If you have any other questions, please feel free to contact us. Our team looking forward to working with you and get better together!
Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com
Location:
India
Tuesday, 23 October 2018
BS EN 1838:2013 Emergency Lighting Testing
BS EN 1838:2013 Emergency Lighting Testing |
BS EN 1838:2013 Emergency Lighting Testing
First of all, What is BS EN 1838:2013 standard? This standard states general rules for emergency escape lighting and standby lighting systems installed in an office, property, site, building or working place where such systems are required. These areas are predominantly where the public or workers have access. | ||
Use of BS EN 1838 can help save life and unnecessary anxiety and confusion can be alleviated by strategically placed visible signs indicating the way out of a location. | ||
Types of emergency lighting at a location with the objective : | ||
S.No | Type of lightning | Objective |
1 | Emergency lighting | to ensure the safety lighting is provided on the dot in a specified area when the normal mains power supply to the usual lighting installation fails. |
2 | Emergency Escape lightning | to enable a safe exit from a location and/or building in the event of failure of the mains’ normal supply |
3 | Emergency Escape route lightning | to enable the safe exit from a location or building for occupants by providing appropriate visual conditions and direction finding on escape routes, and in special locations, and to ensure that firefighting and safety equipment can be readily located and used. |
4 | Anti Panic Lightning | to enable safe movement of occupants towards escape routes by providing appropriate visual conditions and direction finding. |
5 | High-Risk task area lightning | to the safety of people involved in a potentially dangerous process or situation and to enable proper shutdown procedures to be carried out for the safety of other occupants of the location or the building. |
This standard is for : | ||
1. Lightning Engineers | ||
2. Electrical Contractor | ||
3. Landlords, employers and any individual with responsibility for premises such as hospitals, care homes, hotels, schools, laboratories, theatres, cinemas, concert halls, sports halls, libraries, shops, museums and sports stadium. | ||
Revised editions of BS EN 1838 has : | ||
Illumination of the points of emphasis has been clarified and improved and external illuminations have been clarified as needed to extend to a place of safety | ||
Illumination of fire alarm call points and first aid posts are now consistent, regardless of location | ||
The colour and style of safety signs is amended to the revised ISO format | ||
A deviation of some countries has been amended. | ||
Every employer is required to carry out a risk assessment to identify the risks to people who enter the employer’s premises; | ||
Measures to be taken on basis of Risk Assessment | ||
· Provision of safe means of escape | ||
· Emergency lightning | ||
· take into account the needs of people with disabilities | ||
Emergency Lightning Design Checklist : | ||
1. Inspection of the risk assessment | ||
2. The time span of the emergency lighting | ||
3. Discover emergency escape routes and take account of possible dangers. | ||
4. Find the locations of fire alarm call points, firefighting equipment and fire safety signs | ||
5. Determine the type of emergency lighting system | ||
6. Means of isolation for testing and/or maintenance | ||
7. Coordination/interface with luminaire manufacturers where main luminaires are to be converted into emergency lighting luminaires | ||
8. Discover the exit sign requirements | ||
9. Find any high-risk areas | ||
10. Open areas larger than 60m² floor areas need to be identified | ||
11. Need for external illumination outside final exit doors and on a route to a place of safety. | ||
Locations : | ||
It is paramount that the emergency luminaires are placed to give suitable illuminance in the event of a failure of the normal lighting. | ||
S.no | Area | Details |
1 | Open Area | Open areas are often called anti-panic lighting. These are areas larger than 60m² floor area or maybe areas identified by the fire risk assessment as requiring safety illumination |
2 | Emergency Exit and escape route | Emergency exits and escape routes should be provided with signs |
3 | External areas in the immediate vicinity of exits | In order to assist dispersal to a place of safety, the external areas in the immediate vicinity of final exits should be illuminated in accordance with the illumination level for escape routes, given in EN 1838 (BS 5266-7) of not less than 1 Lux |
4 | Lift cars | Lift present a problem because the experience of being confined in the dark within a small space for an indefinite period of time is not only unpleasant but may cause harm to those who are nervous or suffer from claustrophobia |
5 | Moving stairways and walkways | Moving stairways and walkways should be illuminated as if they were part of an escape route in the event of mains failure. |
6 | Toilet Facilities | Toilet facilities exceeding 8 metres squared gross area should be provided with emergency lighting as if they were open areas. |
7 | Switch rooms and plant rooms | Emergency lighting should be provided in all motor generator rooms, control rooms, plant rooms, switch rooms and adjacent to main switchgear or control equipment associated with the provision of normal and emergency lighting to the premises. |
8 | Covered car parks | The pedestrian escape routes from covered and multi-storey car parks should be provided with emergency lighting. |
Duration of battery backup: | ||
The battery back-up of the emergency lighting system will depend on the use of the building and the evacuation strategy. 3-hour duration is required in places of entertainment (cinemas, theatres, etc) and for buildings that have a sleeping risk (hotels and guesthouses, etc.). | ||
Lumination Levels | ||
The level of illuminance required depends on the function of an area. | ||
Certain specific locations require a specific illuminance and response time the below table gives the locations and response time. | ||
Location | Minimum luminance(Lux) | |
Kitchens | 15 | |
First aid rooms | 15 | |
Treatment rooms | 50 | |
Refuges | 5 | |
PlaPlant rooms switch rooms & emergency winding facilities for lifting rooms, switch rooms & emergency winding facilities for lifts | 15 | |
Fire alarm control and indicating equipment | 15 | |
Reception areas | 15 | |
Panic bars & pads or security devices | 5 | |
Swimming pool surrounds and diving area | 5 |
If Your Buyers Demanding for Emergency Lighting Testing – Contact Now!
Kindly send us the following Details, So that we can provide you with a quotation for the same:
- Product Name, Technical Specifications, and Brochure
- Product Images
- Total Number of Samples Required: 2
Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!
Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com